Flue Dampers
Automatic solid fuel and gas
Closes the flue when the system is off. If power is lost, each fails the safe way for its fuel: solid fuel opens, gas closes and seals. Every X-VENTISO damper uses the same 4-pin Molex, regardless of size. Choose the damper by fuel, not by controller.
- Solid fuel automatic
- Gas top-mount
- Gas inline

- Solid fuel
- Fully automatic, UL 378
- Gas
- Sealed, top-mount and inline
- Fail-safe
- Solid fuel fails open, gas fails closed
- Alarm
- Audible and visual, via controller
- Connection
- 4-pin Molex, any size
New
Automatic. Solid Fuel. Finally.

Wood fireplaces have always depended on a person. Open the damper before the fire, or the room fills with smoke. Close it after, or the chimney pulls heated air out of the house all night. And the handle is usually inside the firebox, reached by hand.
The X-VENTISO automatic solid fuel damper puts it on a switch. Turn the system on and the damper opens, proves it is open, and alarms if it is not. It stays open until the switch is turned off. Built for wood from the start, tested and listed to UL 378, and if power is lost, it fails open.
With or without a draft inducer. Run it on XV-WBC or XV-WBC-DUO with an XV Series draft inducer, or on the stand-alone XV-SFDC where the chimney drafts on its own.
Built for wood
Wood Is Harder on a Damper. This One Was Built for It.
Creosote
A Deliberate Gap
No seal to foul or stick. A small, deliberate gap tolerates creosote buildup, so the damper keeps moving season after season.
Proven
Open, or You Know
The controller confirms the damper is open. If it is not, an audible and visual alarm says so.
Fail-safe
Fails Open
If power is lost, the damper opens, so the flue is never left blocked with a fire in the box.
Plug-in
One Connector
The same 4-pin Molex as every X-VENTISO damper. Runs on Controlled Power WBC and WBC DUO, or on the stand-alone SFDC.
Built to keep a wood flue clear and controlled, not airtight. For a sealed flue, use a gas damper on a gas appliance.
Manual vs automatic
A Pull Chain in the Firebox, or a Switch on the Wall.
| Row | Manual damper | X-VENTISO automatic solid fuel damper |
|---|---|---|
| Before the fire | Opened by hand, if someone remembers | Opens when the system is switched on |
| If it is not open | Smoke comes into the room | Audible and visual alarm |
| After the fire | Closed by hand inside the firebox, or left open | Stays open until the switch is turned off, then closes. Turn it off once the fire is fully out. |
| Proof it is open | None | Proven by the controller |
| Power loss | Stays where it was left | Fails open |
Gas dampers
Want a Damper That Closes? On Gas, It Has to Be Automatic.
In an energy-code building, an open flue is the largest hole in the envelope. It leaks conditioned air around the clock, and it shows up on the blower door test.
Gas code takes the manual damper off the table. NFPA 54 does not allow a manually operated damper in a gas appliance vent, and gas log instructions call for the fireplace damper to be removed or fixed open. A damper left closed on a burning gas appliance sends carbon monoxide into the room, so code keeps the flue open around the clock.
If the design calls for a damper that actually closes, code allows one path: an automatically operated vent damper of a listed type. X-VENTISO gas dampers are listed to UL 378 for gas appliances, and the controller will not let the appliance fire until the damper proves open.
X-VENTISO gas dampers close on a silicone seal, not a gap. Top-mount and inline, sized to the flue.

Sealed
Closes Tight
A silicone rubber seal closes the flue whenever the appliance is off.
Proven
Open Before Ignition
The controller confirms the damper is open before the appliance can light.
Fail-safe
Fails Closed
If power is lost, the damper closes and seals the flue. The appliance cannot light until power returns and the damper proves open again.
Plug-in
One Connector
The same 4-pin Molex for every size and every X-VENTISO controller.
Code basis
Why Automatic: What the Code Says.
| Code | What it says | X-VENTISO |
|---|---|---|
| NFPA 54 (2018), 12.14 | A manually operated damper shall not be placed in any appliance vent connector. | No handle. The damper opens and closes on the controller. |
| NFPA 54 (2018), 10.6.2.1 | Decorative gas appliances in a vented fireplace are installed per the manufacturer's instructions. Gas log instructions call for the fireplace damper to be removed or fixed open. | The fireplace damper stays fixed open as instructed. The X-VENTISO gas damper closes the flue when the appliance is off. |
| NFPA 54 (2018), 12.15 | An automatically operated vent damper shall be of a listed type. | UL 378, gas appliances. ETL Listed, Intertek control no. 4007025. |
| NFPA 211 (2019), 9.9.1, 9.9.4, 9.9.5 | No manual dampers in chimneys or vents serving gas appliances. Automatic dampers shall be listed and installed per the damper and appliance listings. Gas venting follows NFPA 54. | No handle. Listed to UL 378 for gas appliances, ETL Listed, Intertek control no. 4007025. Installed per the X-VENTISO installation manual and the appliance manufacturer's instructions. |
| California Energy Code, 150.0(e) | Fireplaces need a flue damper with a readily accessible control. With gas logs installed, the damper is blocked open where the instructions or the mechanical code require it. | Controlled from the room by the system switch. Closes whenever the appliance is off. |
International Fuel Gas Code and IRC fuel gas chapter: a manually operated damper shall not be placed in any appliance vent connector, and an automatically operated vent damper shall be of a listed type.
Which controller
Choose by Fuel.
| Damper | Fuel | Pairs with |
|---|---|---|
| Automatic solid fuel | Solid fuel | WBC · WBC DUO · SFDC |
| Gas top-mount | Gas | GBC · GBC DUO · Meridian · GFDC |
| Gas inline | Gas | GBC · GBC DUO · Meridian · GFDC |
Every X-VENTISO damper is listed to UL 378. Gas dampers are listed for gas appliances only: they close on a silicone seal and fail closed. The solid fuel damper has a deliberate gap for creosote and fails open. Never put a gas damper on a wood fire.
On power loss
Each Damper Fails the Safe Way for Its Fuel.
Solid fuel: fails open
A wood fire keeps burning when the power goes out, so the flue has to stay clear. The solid fuel damper fails open, and the flue is never left blocked with a fire in the box.
WBC and WBC-DUO sound their audible and visual alarm if power is lost while the system is on, on battery backup, as NFPA 211 expects.
Gas: fails closed
A gas fireplace on an X-VENTISO system cannot light without power: the interlock lets the appliance fire only once the damper proves open. If the fire is on when the power goes out, it shuts off: the X-VENTISO controller sits in the connection to the gas valve, so losing power opens the interlock and the valve closes, even on an ignition with battery backup. Then the gas damper closes and seals the flue.
The house stays sealed through the outage: no conditioned air lost up the chimney, no cold air falling down it. When power returns, the damper opens and proves open before the appliance can light.
Specifications
Damper Specifications.
| Specification | Automatic solid fuel | Gas |
|---|---|---|
| Configurations | Top-mount only | Top-mount, inline |
| Sizes | 8", 10", 12", 13", 14", and 16", matched to the draft inducer (see Part Numbers download) | Inline: 8", 10", 12", 13", 14", and 16" (XV-INLD-8 to XV-INLD-16). Top-mount: 8", 10", 12", 13", 14", and 16", matched to the draft inducer (see Part Numbers download) |
| Material | 316L stainless body | Top-mount: 316L stainless body. Inline: 316L stainless body; heat shield and slip fittings galvanized steel |
| Seal | None, deliberate gap for creosote | Silicone rubber |
| Listing | UL 378, solid fuel; ETL Listed, Intertek control no. 4007025 | UL 378, gas appliances only; ETL Listed, Intertek control no. 4007025 |
| Alarm | Via controller (WBC, WBC-DUO, SFDC): audible and visual | Via controller |
| Code basis | NFPA 211-2019: listed automatic damper (9.9.4), operable from the room (11.2.9.2) | NFPA 54-2018: listed, automatically operated vent damper (12.15), interlocked with the appliance |
| Connection | 4-pin Molex | 4-pin Molex |
| Actuator | 24 V, spring return to open | 24 V, spring return to closed, ~5 seconds |
| Power loss / fault behavior | Fails open | Fails closed: seals the flue; the appliance cannot light until power returns and the damper proves open |
Downloads
Documents and Drawings.
- Part NumbersPDF (PDF, opens in a new tab)
- Submittal SheetsPDF · One per damper family
- Dimensional DrawingsPDF · CAD where noted
- Installation ManualPDF · All three damper families (PDF, opens in a new tab)