Outdoor Living
Covered patios, loggias, and outdoor rooms
The fire outside, without the smoke in your face. Under a roof, smoke rolls back toward the people the fire is for. A draft inducer at the end of the run gives it one way to go: out and away.
- Where
- Covered patios and loggias
- Fuel
- Gas and wood
- Material
- 316L stainless
- Discharge
- 45° up and away
- Weather
- Rain collar
Outside is all wind
Outside, the Wind Is Always Part of It.
Indoors, a chimney fights the house. Outdoors, it fights the weather. A covered patio is open on one side or more, so wind moves straight through it, and the roof above the seating area traps whatever smoke the chimney does not carry off.

See-through fireboxes are open on both faces, so wind can push across the fire from either side. Short outdoor chimneys have little natural lift to begin with. A draft inducer at the end of the run pulls the whole flue and sends exhaust away from the roofline, whichever way the wind blows.
Natural draft needs perfect conditions. Outdoors, conditions change every hour.
Built for the weather
Built to Live Outside.
Housing
316L Stainless
Housing and impeller in 316L stainless, for rain, sun, and salt air.
Rain
Rain Collar
Keeps weather out around the lower draft inducer body.
Controller
NEMA 1, Under Cover
The controller does not need conditioned space. It does need protection from rain and direct sun: mount it under cover. Need more protection? Custom enclosures are available on request.

The system
The Same Complete System as Indoors.
Draft
XV Series
Listed for gas and solid fuel. Sized to the flue and mounted at the end of the run, vertical or horizontal, wherever the design terminates.
Control
Meridian or Controlled Power
Proven draft, as indoors. On gas, interlocked with the appliance. On wood, a built-in audible and visual alarm.
Damper
Top-Mount or Inline
Top-mount dampers are built for the chimney top, where the weather is. Inline dampers install inside the chase.
Sound
Vibration Dampener
Keeps motor vibration at the draft inducer, away from the seating area.
Easy to install. Plugs into a standard 120 V outlet. Factory-wired, plug-in Molex connections from draft inducer to controller. No hardwiring. Not sure what the job needs? Send plans or call 800.642.2920 and we size it with you.
Quiet outdoors
Sound Goes Up, Not Across the Patio.
Outdoors, the draft inducer is often only a few feet above the seating area. The 45° upward discharge throws exhaust and sound up and away from the roofline instead of across it, and the controller runs the draft inducer only as hard as the fire needs.
Neighbors are part of the outdoor room too. The fire should be the loudest thing on the patio.
When is it outdoors
When Is an Outdoor Room Still Outdoors?
Outdoor gas fireplaces are certified to ANSI Z21.97 / CSA 2.41, Outdoor Decorative Gas Appliances. Installation instructions for appliances certified to that standard generally treat a space as outdoors only when its shelter is no more enclosed than one of the first three plans below.

The two walls can be parallel or meet at a corner. Glass, sliding panels, and doors that can close do not count as open. Enclose the space beyond these limits and it is an indoor installation, under the National Fuel Gas Code (NFPA 54) for gas and NFPA 211 for wood. Either way, the draft is the same problem, and X-VENTISO ships the same complete system.
Code
Even Where No Code Requires It.
Outdoors, specific venting codes may not apply. X-VENTISO ships the same complete system on every job anyway: proven draft, interlocks, and alarms, in the box. An outdoor fire is still a fire, and the people around it deserve the same protection as the people inside.
What Ships in Every BoxCommon questions
What People Ask Us.
- Q.01Does an outdoor fireplace need a draft inducer?
- Maybe not, on a calm night with a tall chimney. But we can't see the wind, the trees, or the roofline from a drawing, and outdoors those change by the hour. If the fire sits under a roof near people, proven draft is the way to stop depending on the weather.
- Q.02Will it work on a see-through fireplace?
- Yes. It pulls the flue from the end of the run, so it works whichever face the wind hits. See-through and multi-flue designs are sized as a system; send plans and we size it with you.
- Q.03Can it go on an existing outdoor fireplace?
- Often, yes. We make custom adapters for any chimney size or setup. Send photos of the chimney top and the fireplace, and the flue size, and we will tell you what it takes.
- Q.04Will the neighbors hear it?
- The 45° discharge sends sound up and away, and the controller runs the draft inducer only as hard as the fire needs. Its sound power is independently tested and published.
- Q.05What about rain and salt air?
- The housing and impeller are 316L stainless, a rain collar protects the lower body, and top-mount dampers are built for the chimney top. The controller is NEMA 1: it does not need conditioned space, but it does need to be under cover, out of rain and direct sun. For extra protection, we build custom enclosures on request.
- Q.06What about a pizza oven in the outdoor kitchen?
- Wood-fired ovens burn hotter and longer than a fireplace. See Pizza Ovens for how we handle them.