Automatic.Solid fuel.Finally.
A fully automatic solid fuel damper, listed to UL 378, with an audible and visual alarm for NFPA 211. Pairs with WBC, WBC DUO, and SFDC.
Meet the damper
home
Ventilation systems for combustion and exhaust
X-VENTISO draft inducers, controls, and makeup air work as one system, so every combustion and exhaust appliance in the building vents the way it should. Code Compliant, Every Time.1
The pressure problem
Modern construction seals the building envelope tighter every year. A single 400 CFM exhaust appliance can pull a tight building envelope negative by roughly 7 Pa. An open fireplace can begin to spill at 3 to 4 Pa.
When the building pulls harder than the chimney lifts, the chimney loses.
400 CFM exhaust, tight building envelope≈ 7 Pa
Open fireplace begins to spill3 to 4 Pa
The fix: mechanical draft, with makeup air to match.
Typical values. Actual depressurization depends on building size, tightness, and exhaust flow.
Systems, not parts
Draft inducers built for pressure, WSPRDraft flue silencers tested to ISO 7235, and vibration isolation that keeps the draft inducer from talking to the structure.
Plugs into a standard 120 V outlet. Factory-wired from draft inducer to controller, with a service disconnect at the draft inducer. Connect the Molex, done. Proven draft, interlocks, and alarms ship in the box.
We work with your architect and engineer. You install. Send the plans and we recommend the flue size and the right equipment for the system. Flue calculator and tech line at 800.642.2920.
The lineup

Draft inducers
XV150 · XV250 · XV350. Built for pressure, listed for gas, solid fuel, and grease.
Explore XV Series
Self-modulating control
Meridian and Meridian DUO. Measures the flue and the space it serves. Nothing to dial in.
Explore Meridian
Draft control
WBC, GBC, and their DUOs. Proven draft and a complete code package in every box.
Explore Controlled Power
Makeup air
25 to 400 CFM, sensing its own zone. Replaces the air your exhaust removes.
Explore VMASS
Complete the system
A fully automatic solid fuel damper, listed to UL 378, with an audible and visual alarm for NFPA 211. Pairs with WBC, WBC DUO, and SFDC.
Meet the damper
Meridian measures the flue and the space it serves, modulating the draft inducer continuously with XV-FLUX. Fully automatic, no commissioning required. Two flues? Meridian DUO handles each one independently from a single controller.
Explore Meridian
Listed to UL 378 · UL 705 · UL 705 Supplement SC · CSA B255. CAD, spec sheets, and BACnet/Modbus integration in Spec & Support.