Code Compliance
Compliance shouldn't be an upgrade
NFPA 54 requires the gas appliance to be interlocked with proven draft. NFPA 211 requires an audible and visual alarm on mechanically drafted solid fuel appliances. Most draft kits ship with a speed control and sell the rest separately, and the rest is what gets skipped. X-VENTISO controllers ship with it built in.1
Code Compliant,
Every Time.1
Why it matters
A Speed Control Is Not a Draft Control.
A speed control, often called a rheostat, sets how fast a fan spins. It cannot tell whether the chimney is drafting, and it cannot stop the appliance when it is not. The codes installers work to require both.
Why the codes got here: How Houses Got TightIn the box
Typical Draft Kit vs. X-VENTISO.
| Feature | Typical draft kit | X-VENTISO controller package |
|---|---|---|
| Draft inducer | Yes | Yes |
| Speed control (rheostat) | Yes | Meridian sets itself |
| Proven draft, gas | Sold separately | Pressure-proven, stack probe and tubing in the box |
| Proven draft, solid fuel | Sold separately | Proven by draft inducer operation, built into the controller |
| Gas interlock (NFPA 54) | Sold separately | In the box |
| Audible and visual alarm (NFPA 211) | Sold separately | Built into the Controlled Power controller |
| Wiring | Field-wired by installer | Factory-wired, plug-in |
Gas: NFPA 54 (National Fuel Gas Code)
Four Things Gas Code Asks For.
- NFPA 54
- 12.4.3.5
Proven Draft
Gas to the main burners shuts off when the draft system is not performing.
X-VENTISO
GBC and Meridian prove draft by pressure, interlocked with the gas control. Stack probe and tubing in the box.
- NFPA 54
- 12.4.3.1
Listed Draft Equipment
The mechanical draft system is listed to UL 378.
X-VENTISO
XV Series draft inducers are listed to UL 378.
- NFPA 54
- 12.14
No Manual Damper
A manual damper is not permitted in the vent connector. Gas logs installed per their listing usually call for the damper fixed open.
X-VENTISO
If the design calls for a damper that closes, it has to be automatic.
- NFPA 54
- 12.15
Automatic, and Listed
An automatically operated vent damper is permitted, and it has to be listed.
X-VENTISO
Gas dampers listed to UL 378 for gas appliances. Proven open before ignition; fail closed on power loss.
Solid fuel: NFPA 211
What NFPA 211 Asks of a Draft Inducer on Wood.
- NFPA 211
- 4.1.2.5
Proven Draft
The mechanical draft system has to prove it is working.
X-VENTISO
WBC and WBC-DUO prove draft by draft inducer operation.
- NFPA 211
- 4.1.2.5
Alarm in the Room
An audible and visible warning in the same room if the draft system fails.
X-VENTISO
Built into the wall control (MUC).
- NFPA 211
- 4.1.2.5
Power Loss, Battery Backup
The warning also sounds if power is lost while the system is switched on, with battery backup.
X-VENTISO
Two CR2032 lithium cells in the MUC. No alarm just because the house has no power while the fireplace is off.
- NFPA 211
- 4.1.2.5
Smoke and CO Alarms
A smoke alarm and a listed carbon monoxide alarm in the same room.
By the building
Supplied by the building. On a retrofit, confirm both are present and working.
Solid fuel: automatic dampers
An Automatic Damper on a Wood Fireplace.
- NFPA 211
- 9.9.4
Listed, Installed per Listing
Automatically operated dampers shall be listed, and installed by a qualified installer per the damper and appliance listings.
X-VENTISO
Listed to UL 378. ETL Listed, Intertek control no. 4007025.
- NFPA 211
- 11.2.9.2
Operable From the Room
On a masonry fireplace the damper may sit at the top of the flue, and it has to be operable from the room containing the fireplace.
X-VENTISO
A wall switch, in the room.
- Inspection
Clear Flue, Working Damper
A chimney inspection checks that a top-mounted damper does not obstruct the flue, and that the damper opens and closes.
X-VENTISO
Proven open by the controller every time the system is switched on.
- Beyond code
Fails Open
If power is lost with a fire in the box, the flue has to stay clear.
X-VENTISO
Spring return to open. On WBC and WBC-DUO, an audible and visual alarm if power is lost while on, on battery backup. XV-SFDC has no battery: a UPS is recommended.
With a draft inducer, the damper runs on WBC or WBC-DUO. On a chimney that drafts on its own, it runs on the stand-alone XV-SFDC.
Keep it working
Three Things at Every Annual Inspection.
- Test
Test the Alarm
With the system on, unplug the controller.
What you should see
The alarm should sound, audible and visual.
- Replace
Replace Both Cells
Two CR2032 lithium coin cells sit in the MUC battery tray.
When
Replace both every year, or sooner if the green light flashes for low battery.
- Mute
Mute Is Not Off
Mute silences the buzzer for 5 minutes.
What happens next
If the fault has not cleared, the alarm sounds again, and keeps repeating until it is cleared.
Makeup air
Interlocked When Code Requires It.
- NFPA 211
- 4.1.2.2 to 4.1.2.4
No Spillage, Tested
A mechanical draft system must not cause other combustion equipment to spill, verified by testing with the other exhaust equipment running.
X-VENTISO
Draft and makeup air are sized together.
- IRC M1503.6
- IMC 505
Over 400 CFM of Exhaust
Exhaust over 400 CFM needs makeup air approximately equal to what it removes (IRC M1503.4 in editions before 2018).
X-VENTISO
VMASS, interlocked through XV-INTG or a low-voltage contact closure.
- NBC 9.32
Canada
The National Building Code requires the same protection against depressurization, as adopted provincially.
X-VENTISO
VMASS modulates to the zone's actual pressure once running.
Listings
Listed for the U.S. and Canada.
| Listing | Covers |
|---|---|
| UL 378 | Draft equipment |
| UL 705 | Power ventilators |
| UL 705 Supplement SC | Restaurant exhaust |
| CSA B255 | Draft equipment, Canada |
| ULC-S645 | Restaurant exhaust, Canada |
| Controllers: Controlled Power, Meridian, damper controls | UL 508 industrial control and UL/ULC 378 draft equipment, ETL Listed, Intertek control no. 4007025 |
| Dampers | UL 378 draft equipment. Gas dampers: for gas appliances. Not for solid fuel. Solid fuel damper: for solid fuel. ETL Listed, Intertek control no. 4007025 |
Your inspector
Built to Make the Inspection Easy.
Codes are adopted and amended locally, and the authority having jurisdiction makes the final call on every installation. Everything on this page is here to make that call easy: the listings, the matrix, and the installation instructions an inspector will ask for.
Sections cited from NFPA 54 (2018 edition) and NFPA 211 (2019 edition). Your jurisdiction may have adopted a different edition.