Damper Controls
For applications without a draft inducer
Stand-alone gas and solid fuel damper controls. When the chimney drafts on its own but the damper still has to be proven open, GFDC and SFDC do the job.

- GFDC
- Gas, interlocked
- SFDC
- Solid fuel, alarmed
- Proves
- Damper open
- Wiring
- Molex, plug-in
Gas
GFDC: Proven Open Before Ignition.
GFDC proves the damper open before the gas control can ignite. It is interlocked like every X-VENTISO gas controller: its damper proven relay sits in the appliance's ignition circuit, so if the damper does not prove open, the appliance does not light.
Connects to SIT Proflame 2 (terminal blocks factory-connected on the ignition lead), Dexen and Resideo / Honeywell modules, and to Robertshaw 780-715 U through the XV-IGN-ADPT-RS adapter. Home automation, a hearth remote receiver or a wall switch makes the call. When the call ends, the damper stays open for a 30-second post-purge, then closes.

Solid fuel
SFDC: Opened From the Wall, Alarmed if Not.
SFDC opens the automatic solid fuel damper from a wall switch in the room, and alarms if the damper does not prove open. The wall switch is by others: any single-pole switch, a hearth remote receiver or an automation relay, dry contact.
Leave the wall switch ON until the fire and all coals are completely out. Switching off closes the damper after a 30-second post-purge. Keep the XV-SFDC out of All Off, Away, Goodnight and scheduled-off automation scenes.
On power loss the damper springs open. The SFDC has no battery: connect it to a UPS (recommended) so the alarm stays active through an outage.

In the box
What Ships, What You Add.
In the box
| Controller | Factory-sealed, with a 6 ft power cord |
|---|---|
| Ignition lead | 4 ft, black 4-pin Molex. GFDC: two SIT Proflame 2 terminal blocks factory-connected |
| Manual | XV-IM-DMP-CTRL installation manual |
Sold separately
| Damper | GFDC: XV-GFD, XV-TMD or XV-INLD. SFDC: XV-SFD |
|---|---|
| SFDC wall switch | By others: any single-pole switch |
| Extensions | XV-DAMPEREXT 20, 50 or 100 ft; XV-IGNEXT 20 or 50 ft |
| GFDC ignition adapters | XV-IGN-ADPT-RS (Robertshaw); XV-IGN-PFAK (automation on Proflame 2) |
| Several flues | XV-INTG: damper controls of the same fuel on one call |
Specifications
Damper Control Specifications.
| Specification | GFDC | SFDC |
|---|---|---|
| Fuel | Gas | Solid fuel |
| Call to run | Appliance ignition control, automation, remote or switch: dry contact | Wall switch (by others), dry contact |
| Compatible dampers | Gas top-mount and inline (XV-GFD, XV-TMD, XV-INLD) | Automatic solid fuel damper (XV-SFD) |
| Damper proven relay | Dry contact, 3 A @ 30 VDC, 3 A @ 250 VAC | Not used |
| Post-purge | 30 seconds after the call ends | 30 seconds after switch-off |
| Alarm | Damper position: display and buzzer; the appliance stays off | Damper position: display and buzzer |
| On power loss | Gas damper fails closed; the appliance cannot fire | Damper springs open. No battery: UPS recommended |
| Designed for | The NFPA 54 vent damper interlock (12.15): the appliance cannot fire until the damper proves open | NFPA 211 automatic dampers: a listed damper installed per its listing (9.9.4), operable from the room containing the fireplace (11.2.9.2) |
| Electrical rating | 120 VAC, 60 Hz, 1.0 A; 6 ft cord | 120 VAC, 60 Hz, 1.0 A; 6 ft cord |
| Display | View-only, behind a clear protective cover | View-only, behind a clear protective cover |
| Operating environment | 5 to 104°F (-15 to 40°C), non-condensing | 5 to 104°F (-15 to 40°C), non-condensing |
| Enclosure | Factory-sealed, NEMA 1 (indoor). 5-1/8 x 9-3/8 x 3-1/8 in., surface mount | Same |
| Listings | UL 508 Industrial Control · UL/ULC 378 Draft Equipment. ETL Listed, Intertek control no. 4007025 | UL 508 Industrial Control · UL/ULC 378 Draft Equipment. ETL Listed, Intertek control no. 4007025 |
Match the control to the damper. GFDC runs X-VENTISO gas dampers; SFDC runs the X-VENTISO solid fuel damper. Each damper fails the safe way for its fuel, so never pair a gas damper with SFDC or a solid fuel damper with GFDC.
Bench-tested before it is packed. Every X-VENTISO controller is tested on the bench before it ships: damper proving, the gas interlock on GFDC, and the alarm on SFDC. The serial number and the tester's initials are on every controller label.
Downloads
Documents and Drawings.
- Installation ManualXV-IM-DMP-CTRL, PDF (PDF, opens in a new tab)
- Configuration GuidesGFDC top-mount · GFDC inline · SFDC, PDFGFDC top-mountGFDC inlineSFDC
- Compliance MatrixPDF (PDF, opens in a new tab)